| Bluhm Burton Engineering | ||
Large surface exhaust fan installation. |
Modern refrigeration plant, cooling towers and water treatment plant. |
Axial fans drive air through horizontal spray chamber air cooler. |
Refrigeration machines in modern plant room. |
3D graphics from VUMA network model. |
|
| Chasm Consulting | ||
Ventsim Visual can rapidly build and display ventilation models by importing data from existing mine planning or CAD software; models are built in 3D, and can be rotated, zoomed and animated in real-time. |
Ventsim training can rapidly skill personnel in the use of the many advanced features of the program; training can be performed in formal groups, or one-on-one in a mining environment. |
Existing mine workings and 3D solids can be imported into Ventsim Visual to provide a stunning 3D visualisation of your ventilation network; up to 70 different types of ventilation data can be viewed, coloured and animated. |
All aspects of mine ventilation can be modelled in Ventsim Visual, including heat, humidity, airflow, fan pressures, costs, regulator pressures, diesel particulates (DPM), and recirculation. |
||
| Crisp-Air | ||
Crisp-Air’s cold plasma (non-ozone-forming negative ionization) technology for air filtration magnetises the fine particulates to cause clusters, which either lose suspension or become large enough to be captured in filtration systems. |
Crisp Airgineering™ provides air-filtration systems to capture respiratory dust, which are particles less than 10µ that should be reduced in order to improve the workplace and equipment reliability. |
Crisp-Air provides air-filtration systems to capture respiratory dust, or those particles less than 10µ, which should be reduced in order to improve equipment reliability and working conditions. |
Crisp-Air’s self-purging twin filter assembly for air filtration of control and switchrooms. |
Crisp-Air provides dust prevention and removal in site sheds, control and switchrooms. |
|
| Duraduct | ||
Duraduct offers a variety of tubes and piping for mining use. |
Our lockseam tube is used for ventilation ducts, electrical conduit and cable channels. |
Duraduct provides a lockseam tube for use in concrete column forms and other building construction applications. |
| JP Jensen Ventilation | ||
JP Jensen Ventilation is represented by agents around the whole world. |
Long experience and major research work enable JP Jensen Ventilation to produce fabrics with minimal elongation of the base fabric. |
JP-Superjoint - a patented coupling for ductings, to ensure straighter airflow and airtight systems. |
JP Jensen Ventilation always delivers complete ductings; ready to hang up. |
Together with bends, Y-branches, T-branches and cones, which are made out of extremely solid fabrics with welded seams, JP Jensen Ventilation offers a complete and dependable ventilation system. |
|
| Minvent | ||
Ventstop Ventilation Control Unit (VCU) stopping. |
Passline Overhead Protection Unit (OPU) system. |
Passline is suitable for most vertical, dumped or inclined shafts and raise bore holes. |
The Passline overhead protection system has been designed to enhance the safe working parameters of personnel and infrastructure. |
Shaft Plug Void Sealing System (VSS) provides emergency and short-term sealing of an intake or exhaust shaft. |
|
| MVS | ||
Mine Ventilation Services (MVS) provides subsurface ventilation and environmental engineering. |
MVS has been providing ventilation engineering services and computer software to the mining and tunneling industries since 1983. |
MVS specializes in diesel particulate matter (DPM) studies and laboratory analysis. |
| P&H Mine Air Systems | ||
MAS 1000 climate-control unit for roof-mount installation on mining equipment. |
Our MAS 350 unit climate-control unit for mine equipment. |
A haul-truck cab with an MAS 361 climate-control unit. |
A MAS 1300 climate-control unit on an electric blasthole drill. |
An electric shovel with MAS 1500 climate-control units. |
|
| Polyline Industries | ||
POLYDUCT Positive and Negative Pressure Systems are cost effective, modular ventilation ducting that will last the life of your mine. |
4-Way Sections complete with directional valves to control air flow. |
Polyethylene is an excellent material for Fan Silencers, by using a high tech sound foam barrier, we are able to maintain an overall width of less than 50mm. |
Self Regulating Fan Covers are a simple configuration that bolt to the fan flange and automatically opens or closes with air flow from the fan. |
Fire Retardant Anti Static Detonator Boxes have mines department approval in WA and QLD |
|
| Protan | ||
Protan specialises in the design, production and manufacture of webs intended exclusively for use in ventilation ducts. |
A stable yarn is important when you manufacture flexible ventilation ducts: it helps to maintain shape, gives better air transport and less turbulence. |
Protan supplies different types of steelhooks. |
Protan's mounting system has longitudinal suspension with welded PVC eyelets along the entire ventilation duct, which ensures optimal fastening and longitudinal stretching of the duct. |
Both VF and LP coupling models also come in two parts for easy installation of large diameters. |
|
| Rocvent | ||
Rocvent offers a complete line of ventilation fans specifically designed for mine ventilation requirements, and the hostile mining environment. |
Rocvent manufactures inflatable drift barriers for a wide range of applications. |
The low weight and compact design of our self-supporting portable fluid tanks make them easy to set up and transport. |
Rocvent designs and manufactures the finest ventilation ducting system on the market today. |
Rocvent is an agent for the Haggloader series of mining loaders for high speed tunnelling and production applications. |
|
| Summit Matsu Chilling Systems | ||
SDA-7-280kW for Boddington Gold Mine (2 x 140kW modules mounted together) |
MWC-8-155kW water chiller, process cooling coils in tank evaporator, includes tank and pump. |
MWC-7-85RW to 220kW water chiller, dual circuit shell and tube evaporator, optional plc control with lead lag, suitable for water / glycol solutions. |
Process and air con chillers 22kW-54kW, PC board diagnostic system as standard, single or dual compressors with lead lag option, designed for extremely hot weather. |
||
| TLT-Turbo | ||
Axial mine ventilation fan, vertically arranged and removable. |
Removable axial mine fans with motor inside the fan hub and with blade adjustment system. |
Axial fan with a power consumption of 13,5 MW. |
Formula 1 – wind tunnel. |
Axial Flow fans for the “Bad Godesberg” road tunnel (2 km length). |
|